Technical specifications |
MODEL |
JK-PB-6000 |
Paint Spray Chamber |
|
Booth inside Dimension (LxWxH) |
(6000x4000x3500)mm |
Front Door Opening (LxH) |
(3000x3300)mm |
Illumination |
45W Flame Proof Lighting Qty-08 |
Material |
Corrosion Resistant, fabricated MS Sheet |
Exhaust Filter |
|
Fan Motor |
10 HP,415V/3Phase, Noiseless |
Motor Type |
Flame Proof |
Fan Type |
Axial flow fan |
Paint trap filter |
Glass fiber type filter |
Fan Capacity |
Atleast 7500 CFM |
Air Intake Filters |
|
Pre-filter Assembly (WxH) mm |
(500x750)mm Qty-06 |
After Filter |
Minimum 15mm in thickness |
Filter media |
Wire Mesh type |
Lighting |
|
Power Supply |
220 volts, 50 Hz Single phase |
Illumination lights outside the booth |
Flame proof inside lights |
|
Switch panels with MCB switches. |
Power consumption |
|
Illumination |
0.5 KW/220 V/50Hz |
10 HP Approx, 3 Phase |
|
Front Main door |
|
The Front door Should be provided in two leaves. Each leaf of door should be provided with dual vision window, double layer with one glass |
The door should be properly sealed from all the sides to prevent the suction of dust inside the spray booth. |
Doors should be fabricated with minimum 1.00mm corrosion resistant sheet |
The doors should be provided with rubber sponge to minimize the leakage. |
Paint Spray Chamber |
Paint Spray Chamber should be provided with pre-filters and after-filters Filters should be easily replaceable type and are sealed proof to avoid any leakage. |
Pre-Filters |
Primary stage filter |
Filter Media |
Wire mesh filter |
Ceiling Filter |
Secondary stage filter |
Thickness |
15 mm min |
Filter Media |
Non woven thermal |
Paint trap filter |
|
Paint trap exhaust filter should be provided for suspended paint particle |
Suction hood should be on the wall of the Paint Spray Chamber |
Hood should be connected to duct and followed by weather canopy |
The hood constructed with thick MS Sheet |
Fan Motor |
10HP min |
Capacity |
7500CFM Approx |
Fan type |
Axial flow fan |
Filter material |
Fiber Glass wool |
Ducting |
|
Suitable ducting from suction hood to the exhaust fan is to be provided. Ducting is constructed by 1.5 mm thick MS sheet |
Illumination |
|
Flame proof illumination tube lights should be mounted on the walls of the booth |
The lamps should be wired with suitable copper conductor wiring. |
Flexible PVC conduit is to be used for routing of wires. |
MCB panel should be mounted at suitable location with MCB switches. |
Painting |
|
Inside and outside painting should be in double coated epoxy coating for corrosion resistant |
Additional Requirements of Paint Spray Chamber |
Separate electric control panel for exhaust fan assembly |
Rubber padding for minimizes the leakage. |
Exhaust fans with silencer and canopy |
Manometer for reading the pressure drop across the filter in case of clogging of |
Complete foundations, leveling pads and installation will be provided by the supplier. |
Job loading and unloading arrangements are to be arranged by the suppliers |
Weather protective covers as per the specifications of the booth. |
All wiring and conduits from main supply source to the installation area are to be arranged by the supplier |
Provision of air supply connection in booth chamber |
Provision of door locking. |